Turn laboratory results into clear decisions
Lab Analyzer: Smart analysis of laboratory results
Lab Analyzer runs results through the Medical Decision System: it maps every test to international standards, assesses it by age, sex, physiological state and context, detects diseases early through multi-test patterns and catches sample errors before the result reaches the patient. The patient gets an answer in plain language, the physician in clinical language and the laboratory in the language of quality.
543 · tests with assessment rules
68 · calculated clinical indices
543 · multi-test clinical patterns
290 · conditions, with ICD-10 and SNOMED CT
Capabilities
Standardisation
Test identity via LOINC, units via UCUM and the laboratory’s own reference ranges; code and unit mix-ups are caught automatically.
Seven-level assessment
Every result on an L1–L7 scale, accounting for 25 age groups, sex, pregnancy, menopause and cycle phase.
Multi-test patterns
543 clinical patterns, 290 conditions and 68 calculated indices; findings are coded with ICD-10 and SNOMED CT.
Laboratory error detection
38 rules across 13 error types: contamination, delayed separation, sample mix-ups, and instrument, method and unit errors.
Context and trends
The effects of medication, biotin, fasting, exercise and pregnancy are taken into account; change from previous results is measured against biological variation.
Urgent findings
Four urgency levels; critical values are flagged immediately against referenced limits.
Lab Analyzer: how it works
The result arrives
Via API, FHIR or HL7, or as a PDF, scan or image.
It is checked
Standardisation and sample quality checks.
It is analysed
Level, context, trend, pattern and urgency.
The report is delivered
To the patient, the physician and the laboratory, under your own brand.
Target segments
- Laboratories and laboratory networks
- Clinics and hospitals
- Check-up centres
- Health platforms and apps
- Insurers
Seven steps from number to decision
Every result from the laboratory follows the same path. Each step is grounded in international standards and referenced rules.
Standardisation
112,405 terms with LOINC 2.83 and UCUM units; mix-ups such as procalcitonin vs plateletcrit or Lp(a) in mg/dL vs nmol/L are corrected automatically.
Quality check
Before a result is released, sample, transport, instrument and data entry errors are filtered out.
Assessment
L1–L7 scale: 25 age groups, sex, pregnancy, menopause and cycle phase, based on the laboratory’s own reference range.
Context
The effect of biotin, medication, fasting, exercise, smoking, acute illness and supplements on the result.
Trend
Comparison with previous results: real change measured against EFLM biological variation for 171 tests.
Pattern and condition
543 multi-test patterns, 290 conditions, 68 calculated indices; ICD-10 and SNOMED CT codes.
Report and plan
Patient and physician reports, repeat test rules, Test Plan and e-referral.
Incorrect results are caught before they reach the patient
Lab Analyzer reads every result not only for the patient but also for the laboratory. 38 rules across 13 error types detect sample, transport, instrument and data entry errors and show each finding with its phase and source.
Sample analysis
Potassium
6.8 mmol/L
LDH
412 U/L
AST
58 U/L
Creatinine
74 µmol/L
Sodium
139 mmol/L
Suspected haemolysis
Pre-analytical phase · sample collection
Collect a new sample; critical potassium keeps its urgent flag.
13 error types
- EDTA contamination
- IV fluid contamination
- Lipaemia
- Delayed separation
- Pseudothrombocytopenia
- Sample mix-up
- Haematology inconsistency
- Biochemistry inconsistency
- Instrument index error
- Method interference
- Macro-analyte
- Calculation inconsistency
- Unit and transcription error
Quality report
An error timeline for the period, Pareto analysis by error type, test and analyser, and a concrete action list.
Instrument profiles
Manufacturer method profiles for 67 tests: Roche, Abbott, Siemens, Beckman, Mindray, Sysmex.
Phase and area
Each error is linked to the pre-analytical, analytical or post-analytical phase and to the area: sample collection, transport, instrument, method or data entry.
Every reader in their own language
Patient report
Plain-language explanations, PDF and JSON, in nine languages.
Clinical summary for the physician
Findings, ICD-10 codes, urgency and the next step at a glance.
Health recommendations
Nutrition, supplements and physician referral across 275 conditions.
Topic reports
Women’s and men’s health, menopause, mood, diabetes risk, alcohol use and ovarian age.
Under your own brand
The laboratory’s name and logo on the report cover and on every page.
Test Plan and e-referral
Which test should be repeated and when, and referral of the patient to your laboratory.
Every rule is grounded in a source
Limits, ranges and rules come from scientific sources, each recorded with its level of verification. The system connects to your existing infrastructure through standard interfaces.
2,046 · scientific sources
171 · tests with biological variation
13 · referenced repeat test rules
4 · urgency levels
Connection options
- REST API
- FHIR R4
- HL7 v2 ORU^R01
- PDF, scan and image
Results read from a PDF or image are always analysed after the user confirms them.