Turn laboratory results into clear decisions

Lab Analyzer: Smart analysis of laboratory results

Lab Analyzer runs results through the Medical Decision System: it maps every test to international standards, assesses it by age, sex, physiological state and context, detects diseases early through multi-test patterns and catches sample errors before the result reaches the patient. The patient gets an answer in plain language, the physician in clinical language and the laboratory in the language of quality.

543 · tests with assessment rules

68 · calculated clinical indices

543 · multi-test clinical patterns

290 · conditions, with ICD-10 and SNOMED CT

Capabilities

Standardisation

Test identity via LOINC, units via UCUM and the laboratory’s own reference ranges; code and unit mix-ups are caught automatically.

Seven-level assessment

Every result on an L1–L7 scale, accounting for 25 age groups, sex, pregnancy, menopause and cycle phase.

Multi-test patterns

543 clinical patterns, 290 conditions and 68 calculated indices; findings are coded with ICD-10 and SNOMED CT.

Laboratory error detection

38 rules across 13 error types: contamination, delayed separation, sample mix-ups, and instrument, method and unit errors.

Context and trends

The effects of medication, biotin, fasting, exercise and pregnancy are taken into account; change from previous results is measured against biological variation.

Urgent findings

Four urgency levels; critical values are flagged immediately against referenced limits.

Lab Analyzer: how it works

The result arrives

Via API, FHIR or HL7, or as a PDF, scan or image.

It is checked

Standardisation and sample quality checks.

It is analysed

Level, context, trend, pattern and urgency.

The report is delivered

To the patient, the physician and the laboratory, under your own brand.

Target segments

Seven steps from number to decision

Every result from the laboratory follows the same path. Each step is grounded in international standards and referenced rules.

Standardisation

112,405 terms with LOINC 2.83 and UCUM units; mix-ups such as procalcitonin vs plateletcrit or Lp(a) in mg/dL vs nmol/L are corrected automatically.

Quality check

Before a result is released, sample, transport, instrument and data entry errors are filtered out.

Assessment

L1–L7 scale: 25 age groups, sex, pregnancy, menopause and cycle phase, based on the laboratory’s own reference range.

Context

The effect of biotin, medication, fasting, exercise, smoking, acute illness and supplements on the result.

Trend

Comparison with previous results: real change measured against EFLM biological variation for 171 tests.

Pattern and condition

543 multi-test patterns, 290 conditions, 68 calculated indices; ICD-10 and SNOMED CT codes.

Report and plan

Patient and physician reports, repeat test rules, Test Plan and e-referral.

Incorrect results are caught before they reach the patient

Lab Analyzer reads every result not only for the patient but also for the laboratory. 38 rules across 13 error types detect sample, transport, instrument and data entry errors and show each finding with its phase and source.

Sample analysis

Potassium

6.8 mmol/L

LDH

412 U/L

AST

58 U/L

Creatinine

74 µmol/L

Sodium

139 mmol/L

Suspected haemolysis

Pre-analytical phase · sample collection

Collect a new sample; critical potassium keeps its urgent flag.

13 error types

Quality report

An error timeline for the period, Pareto analysis by error type, test and analyser, and a concrete action list.

Instrument profiles

Manufacturer method profiles for 67 tests: Roche, Abbott, Siemens, Beckman, Mindray, Sysmex.

Phase and area

Each error is linked to the pre-analytical, analytical or post-analytical phase and to the area: sample collection, transport, instrument, method or data entry.

Every reader in their own language

Patient report

Plain-language explanations, PDF and JSON, in nine languages.

Clinical summary for the physician

Findings, ICD-10 codes, urgency and the next step at a glance.

Health recommendations

Nutrition, supplements and physician referral across 275 conditions.

Topic reports

Women’s and men’s health, menopause, mood, diabetes risk, alcohol use and ovarian age.

Under your own brand

The laboratory’s name and logo on the report cover and on every page.

Test Plan and e-referral

Which test should be repeated and when, and referral of the patient to your laboratory.

Every rule is grounded in a source

Limits, ranges and rules come from scientific sources, each recorded with its level of verification. The system connects to your existing infrastructure through standard interfaces.

2,046 · scientific sources

171 · tests with biological variation

13 · referenced repeat test rules

4 · urgency levels

Connection options

Results read from a PDF or image are always analysed after the user confirms them.